Skip to main content

Table 3 Results of repeated measures analysis of variance (PWV)

From: Different Methods for Measurements and Estimation of Pulse Wave Velocity are not Interchangeable

Measurement pairs PWV (m/s)

ΔM*

p

SphygmoCor—Arteriograph 24 h

− 0.307

0.091

SphygmoCor—Mobil-O-Graph 24 h

1.670

0.000

SphygmoCor- ePWV

1.870

0.089

Arteriograph 24 h—Mobil-O-Graph 24 h

1.947

0.000

  1. LSD test; PWV pulse wave velocity, ePWV estimated pulse wave velocity
  2. *The difference between the an average values of the first mentioned and the second mentioned PWV measurement method