- ARTERY 18 Poster Session
- Poster Session II - Models, Methodologies and Imaging Technology II
- Open access
- Published:
P127 Spatial Variation of Reservoir Pressure in Children Assessed with High Fidelity Pressure Measurement in Five Aortic Locations
Artery Research volume 24, page 116 (2018)
Abstract
Objective
To assess whether reservoir pressure (Pres) in young individuals with a compliant aorta is uniform throughout the aorta, as has recently been reported in older adults with cardiovascular disease (1).
Methods
High fidelity pressure was measured with a Verrata wire (Philips Volcano) in 5 aortic locations (ascending-to-abdominal) via pull-back in 11 children with a normal aorta (age 10.4 ± 4.9 years, mean ± SD). Pres was calculated using the ‘pressure-only’ approach (2), with exponential fitting over the whole of diastole (1) (WholeDia) or the period when pressure declined in an approximately exponential fashion (ExpDia).
Results
ExpDia produced a better fit than WholeDia (R2 = 0.99 ± 0.01 vs 0.91 ± 0.11, P < 0.001). Pres amplitude (ΔPres) in the ascending aorta from WholeDia fitting (12.0 ± 4.1 mmHg) was less than with ExpDia fitting (19.0 ± 5.2, P = 0.001). The zero-flow asymptotic pressure (Pinf) obtained from the fitting procedure was negative (non-physiological) in 76% (WholeDia) and 44% (ExpDia) of recordings, but fixing Pinf to 37 mmHg (average of physiological values) had little effect on the resulting ΔPres. ΔPres varied by 5.7 ± 3.0 mmHg (WholeDia) and 7.3 ± 3.7 mmHg (ExpDia) between aortic locations (both P<0.001 compared with zero), corresponding to 44% ± 30% and 38% ± 17% of average ΔPres respectively. Maximum instantaneous spatial differences in Pres amounted to a substantial percentage of ΔPres (45% ± 37% WholeDia; 24% ± 26% ExpDia) and were not reduced by time and/or pressure offsets to align Pres foot.
Conclusion
In young individuals, Pres was sensitive to the fitting period and often resulted in non-physiological Pinf values. Regardless of calculation method or alignment, Pres was not uniform along the aorta.
References
Narayan O, Parker KH, Davies JE, Hughes AD, Meredith IT, Cameron JD. Reservoir pressure analysis of aortic blood pressure: an in-vivo study at five locations in humans. J Hypertens. 2017;35(10):2025–33.
Aguado-Sierra J, Alastruey J, Wang JJ, Hadjiloizou N, Davies J, Parker KH. Separation of the reservoir and wave pressure and velocity from measurements at an arbitrary location in arteries. Proc Inst Mech Eng [H]. 2008;222(4):403–16.
Author information
Authors and Affiliations
Rights and permissions
This is an open access article distributed under the CC BY-NC license https://doiorg.publicaciones.saludcastillayleon.es/creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Mynard, J., Eastaugh, L., Lane, G. et al. P127 Spatial Variation of Reservoir Pressure in Children Assessed with High Fidelity Pressure Measurement in Five Aortic Locations. Artery Res 24, 116 (2018). https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.artres.2018.10.180
Published:
Issue Date:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1016/j.artres.2018.10.180