- Conference Abstract
- Open access
- Published:
P.53 Ascending Aorta Diameter and Pulse Wave Velocity are Increased and Local Hemodynamic is Disrupted in Patients with Blunt Traumatic Thoracic Aortic Injury Treated by TEVAR
Artery Research volume 26, pages S74–S75 (2020)
Abstract
Background
Thoracic endovascular aortic repair (TEVAR) is becoming the preferred treatment option to repair the proximal descending aorta after rupture following blunt traumatic injury. However, hemodynamic and mechanic implications of this intervention are poorly understood. Exploiting the possibilities of 4D flow magnetic resonance imaging, hemodynamics, stiffness and local dilation in the ascending aorta in patients following aortic repair by TEVAR are studied.
Methods
Fifteen apparently healthy individuals who underwent TEVAR implantation after traumatic descending aortic injury and 44 healthy volunteers (HV) underwent 4D flow-MRI. Ascending aorta pulse wave velocity was computed [1]. Moreover, at eight planes equally distributed in the ascending aorta systolic flow reversal ratio, i.e. relative amount of backward flow during systole, and in-plane rotational flow, measuring the strength of helical flow, were computed [2,3].
Results
TEVAR patients and HV did not differ in terms of age, sex, BSA and blood pressure (Table). However, compared to HV, TEVAR patients showed reduced in-plane rotational flow in the distal ascending aorta in patients with TEVAR and increased backward systolic flow in the whole ascending aorta (Figure). Patients with TEVAR had a stiffer ascending aorta, with pulse wave velocity higher compared control (7.8 ± 4.2 vs 5.3 ± 1.9, p = 0.004). Finally, aortic root and ascending aorta diameters were larger in TEVAR patients compared to HV (Table).
Conclusions
The implantation of TEVAR in apparently healthy individuals after traumatic rupture of the proximal descending aorta is associated with altered hemodynamics, higher stiffness and larger aortic diameter in the region proximal to the TEVAR.

In-plane rotational flow (IRF, left) and systolic flow reversal ratio (SFRR, right) in healthy volunteers (black) and TEVAR patients (yellow) in the proximal (planes 1 to 4) and distal (planes 5 to 8) ascending aorta. Stars show statistically-significant differences (p < 0.05).
References
Guala A, Rodriguez-Palomares J, Dux-Santoy L, Teixido-Tura G, Maldonado G, Galian L, et al. Influence of aortic dilation on the regional aortic stiffness of bicuspid aortic valve assessed by 4-dimensional flow cardiac magnetic resonance. JACC Cardiovasc Imaging 2019;12:1020–9.
Dux-Santoy L, Guala A, Teixidó-Turà G, Ruiz-Muñoz A, Maldonado G, Villalva N, et al. Increased rotational flow in the proximal aortic arch is associated with its dilation in bicuspid aortic valve disease. Eur Hear J - Cardiovasc Imaging 2019;20:1407–17.
Guala A, Teixido-Tura G, Dux-Santoy L, Granato C, Ruiz-Muñoz A, Valente F, et al. Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome: a 4D flow CMR study. J Cardiovasc Magn Reson 2019;21:63.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
This is an open access article distributed under the CC BY-NC 4.0 license (http://creativecommons.org/licenses/by-nc/4.0/).
About this article
Cite this article
Guala, A., Sala, D.G., Ruiz-Muñoz, A. et al. P.53 Ascending Aorta Diameter and Pulse Wave Velocity are Increased and Local Hemodynamic is Disrupted in Patients with Blunt Traumatic Thoracic Aortic Injury Treated by TEVAR. Artery Res 26 (Suppl 1), S74–S75 (2020). https://doiorg.publicaciones.saludcastillayleon.es/10.2991/artres.k.201209.063
Published:
Issue Date:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.2991/artres.k.201209.063